DISCONNECTORS
 HV Disconnectors
 Centre Break
 Pantograph
 Horizontal Break Pantograph
 (knee type)
 Earthing Switches
 Operating Mechanisms
 MV Disconnectors
 Indoor Rocking
 Outdoor Rocking
 Centre Break
 Double Break
 Indoor Earthing Switches
 Outdoor Earthing Switches
 Quick Make Earthing Switches
 Operating Mechanisms
 DC Disconnectors
 for Railway Applications
 Operating Mechanisms
 Switch-Disconnectors
 Outdoor Switch-Disconnectors
 Indoor Switch-Disconnectors
 Operating Mechanisms
 Switch Disconnectors
 Fuse Combinations
 Indoor Switch Disconnector
 Fuse Combinations
 Operating Mechanisms
 HV FUSES
 Current Limiting Back-up Fuses
Indoor Fuse Bases
Outdoor Fuse Bases
LIVE WORKING
 Voltage Detectors
 Insulating Sticks
 Rescue Sticks
 Fuse Handle
 Insulating Mats



General


    Güral offers DC Series Disconnectors for DC systems switching solutions. Specially designed for outdoor or subterranian railway applications, DC Series Disconnectors and its driving series products have proven their design efficency and reliability all over the country and have fulfilled the customers' requirements.

   The DC Series Disconnectors are intended for currentless switching in railway applications.

                                                                                                   The flexibility of the design of Güral DC Series Disconnectors allows almost any custom solutions requested by the client, including earthing capabilities of load, supply or both terminals, insulation levels, driving variations and construction assembly types.

DCN Disconnectors


    DCN Disconnectors are normal type DC disconnectors without earthing switches. DCN Disconnectors has the same main circuit electrical characteristics with DCE Disconnectors, and are suitable for indoor use as well as outdoor applications.

DCE 10 Disconnectors


    DCE 10 Disconnectors are equipped with integrated earthing blades at load side, operating either synchronised with the main switch or independently with second drive unit. The mechanical interlock that is designed to prevent operators' false commands is a standard accessory of the product.
   

DCE 20 Disconnectors


    DCE 20 Disconnectors are equipped with integrated earthing blades at supply side, operating either synchronised with the main switch or independently with second drive unit. The mechanical interlock that is designed to prevent operators' false commands is a standard accessory of the product.

DCE 30 Disconnectors


    DCE 30 Disconnectors are equipped with integrated earthing blades both at load and supply side, operating either synchronised with the main switch or independently with second and third drive units. The mechanical interlocks that are designed to prevent operators' false commands are standard accessories of the product.

Base and Shaft


   The DC Disconnectors consists of one pole. One pole DC disconnector consist of a base, two support insulators, one operating rod insulator, a continuous main shaft (hexagonal transmission 27) and a main blade that moves in a vertical plane. All steel parts of the DC Disconnectors switch base are hot-dip galvanized.
   

Insulators


    The disconnectors can be equipped with insulators in accordance with IEC, ANSI or DIN specifications.
   

Current Carrying Part


   The twin sectioning blades and terminals are made of electrolytic copper. Terminals and contact surfaces of blades are nickel or silver plated.

   The twin sectioning blades are pressed on terminal contacts by means of a number of spiral springs depending on required contact pressure due to short-circuit capability, ensure that the current is transferred from the terminal contacts into twin sectioning blades. This blade and contact construction is maintenance free.

   The contacts are self-cleaning, which makes the disconnector suitable for installation in all areas with severe climatic conditions.

Earthing Switch


    Güral DC disconnectors with earthing switches may be equipped with earthing switches, which can be built-on to the supply and/or load side. An mechanical inter lock between the main and earthing shaft is available.

Operating Mechanism

   The DC disconnectors can be single pole operated by means of a motor operated drive mechanism or a hand operated drive mechanism.

   Güral DC disconnectors can be drived by any controlgear model designed by Güral; drive model is to be decided according to application requirements.

Testing


   DC disconnectors are designed and tested in accordance with latest IEC standards.

Installation


   DC disconnectors are completely assembled and adjusted in our workshops. Its design permits both vertical and horizontal mounting.

   The construction is designed so that all disconnectors can be installed at site very easily, without the need of any special tools. For each switchgear an instruction manual for transportation, mounting and commissioning is enclosed. This instruction manual should be strictly followed.

Maintenance


   DC disconnectors supplied by Güral are designed so as to ensure that they are maintenance free.

    However, to guarantee a long and trouble-free service period, we advise that a visual inspection of the contacts and bearing points be carried out at regular intervals.                         

                           

DC Disconnector Technical Data


Standards Compatibility

IEC 61992-1

Railway Applications - Fixed Installations - DC Switchgear, Part 1: General.

Technical Specifications & Variations

Ur 1kV DC

Ir 2000A

BIL 95kV

Ik, tk 50 kA, 1s

Ø Single Circuit

Application Indoor / Outdoor Direct Current Solutions

Types Rocking

Mounting Vertical, Horizontal

Plating Info Chasis: Hot Deep Galvanization

Current Paths : Ag / Ni

Connection Elements: Hot Deep Galvanization, INOX

Insulator Porcelain

Custom Designs Available

Technical Data

Rated Voltage

Ur(VDC)

1000

Power Frequeny Withstand Voltage

 

- to earth

Ud(kV)

38

- across isolating distance

Ud(kV)

45

Lightning Impulse Withstand Voltage

 

- to earth

Up(kV)

95

- across isolating distance

Up(kV)

110

Rated Current

Ir(A)

Up to 2000 A

Rated Short-time Withstand Current

Ik(kA)

Up to 50 kA/1s

Rated Peak Withstand Current

Ip(kA)

Up to 125 kA


Dimensions (mm)

 
 
   
WORKSHOP
Atatürk Sanayi Sitesi, Fahri Korutürk Caddesi, 323 Sokak, No:1, 34900
Hadımköy – ISTANBUL / TURKEY
Tel: +90 212 771 24 95-99 / 771 27 60-61     Fax: +90 212 771 27 62
OFFICE
Rıhtım Cadddesi, C Blok, No:59, Kat:2, Daire: 25, 34425
Karaköy – ISTANBUL / TURKEY
Tel: +90 212 249 82 80      Fax: +90 212 244 25 07
 
 