DISCONNECTORS
 HV Disconnectors
 Centre Break
 Pantograph
 Horizontal Break Pantograph
 (knee type)
 Earthing Switches
 Operating Mechanisms
 MV Disconnectors
 Indoor Rocking
 Outdoor Rocking
 Centre Break
 Double Break
 Indoor Earthing Switches
 Outdoor Earthing Switches
 Quick Make Earthing Switches
 Operating Mechanisms
 DC Disconnectors
 for Railway Applications
 Operating Mechanisms
 Switch-Disconnectors
 Outdoor Switch-Disconnectors
 Indoor Switch-Disconnectors
 Operating Mechanisms
 Switch Disconnectors
 Fuse Combinations
 Indoor Switch Disconnector
 Fuse Combinations
 Operating Mechanisms
 HV FUSES
 Current Limiting Back-up Fuses
Indoor Fuse Bases
Outdoor Fuse Bases
 LIVE WORKING
 Voltage Detectors
 Insulating Sticks
 Rescue Sticks
 Fuse Handle
 Insulating Mats



General


    MV Double Break Disconnector is occasionally used disconnector type in some MV systems.

   Güral MV DBD Series Double Break Disconnectors offer robust and reliable solutions for medium – voltage systems. With variations designed to serve for a wide range of system voltages, Güral MV DBD Series Double Break Disconnectors currently operate worldwide at system voltages from 12kV to 52kV.

   The flexibility of the design of Güral MV DBD Series Double Break Disconnectors allows almost any custom solutions requested by the client, including earthing capabilities of load, supply or both terminals, insulation levels, driving variations and construction assembly types.

                              Güral MV Double Break Disconnectors can be fitted in parallel, in line or even shifted crosswise layouts.

Base


    MV Double break disconnector consists of one or three poles. Each pole consists of a base, two fixed and one rotating support insulators and a main blade that moves in a horizontal plane.

   The base is made of one NPU profiles in which the bearing housing and the rotating part are installed. The bearing housing is supported by two ball bearings for high mechanical loads. The bearing housing is sealed and filled up with special lubricant, to ensure a long and maintenance-free lifetime. All steel parts of the disconnector are hot-dip galvanized.

Insulators


   The disconnectors can be equipped with insulators in accordance with IEC, ANSI or DIN specifications.
   

Current Carrying Part


    The main blade consists of a double-knife construction having silver plated high conductivity copper.

   The fixed contacts for both incoming and outgoing terminals are made of high conductivity copper and silver plated. This contact construction is maintenance free.

   The contacts are self-cleaning, which makes the disconnector suitable for installation in areas with severe climatic conditions.

Earthing Switch


    Güral MV double break disconnectors may be equipped with earthing switches, which can be built-on to the right and/or left hand side.

   The earthing switch is made of a silver-plated copper contact. A mechanical interlocking is provided between Disconnector and Earthing switch.

Operating Mechanism


   The disconnectors and/or earthing switches can be single-pole or gang operated by means of a motor-operated drive mechanism or a manual-operated drive mechanism.

   In case only one drive mechanism is used for gang operation, the poles are interconnected by means of coupling rods.

               MD Series motor drives and HD series hand drives and MVHD series hand drives have aluminium housings and special design auxiliary switches. MD series motor drives also have manual operation by a crank.

Testing


    The double break disconnectors and earthing switches are designed and tested in accordance with latest IEC standards.
   
Installation

    The double break disconnectors and earthing switches are preassembled and adjusted in our workshops as complete as possible.

   The construction is designed so that all disconnectors can be installed at site very easily, without the need of any special tools. Güral provides installation instructions and assembly drawings.

Maintenance


    The disconnectors and earthing switches supplied by Güral are designed so as to ensure that they are maintenance free.

   However, to guarantee a long and trouble-free service period, we advise that a visual inspection of the contacts and bearing points be carried out at regular intervals.



Technical Data and Dimensions


Rated Voltage

Ur(kV)

12

24

36

52

Power Frequeny Withstand Voltage

 

- to earth and between phases

Ud(kV)

28

50

70

95

- across isolating distance

Ud(kV)

32

60

80

110

Lightning Impulse Withstand Voltage

 

- to earth and between phases

Up(kV)

75

125

170

250

- across isolating distance

Up(kV)

85

145

195

290

Rated Current

Ir(A)

Up to 2000 A

Rated Short-time Withstand Current

Ik(kA)

Up to 31.5 kA/3s

Rated Peak Withstand Current

Ip(kA)

Up to 80 kA

Dimensions (mm)

A

250

300

350

450

B

215

305

445

560

C

385

475

615

730

D

155

155

155

155

F

810

910

1010

1210

G

240

240

240

240

K

200

200

200

200

L

200

300

400

500

   
 
   
WORKSHOP
Atatürk Sanayi Sitesi, Fahri Korutürk Caddesi, 323 Sokak, No:1, 34900
Hadımköy – ISTANBUL / TURKEY
Tel: +90 212 771 24 95-99 / 771 27 60-61     Fax: +90 212 771 27 62
OFFICE
Rıhtım Cadddesi, C Blok, No:59, Kat:2, Daire: 25, 34425
Karaköy – ISTANBUL / TURKEY
Tel: +90 212 249 82 80      Fax: +90 212 244 25 07
 
 
copyright © 2007 Güral Elektrik Malzemeleri Ticaret ve Sanayi A.Ş.