DISCONNECTORS
 HV Disconnectors
 Centre Break
 Pantograph
 Horizontal Break Pantograph
 (knee type)
 Earthing Switches
 Operating Mechanisms
 MV Disconnectors
 Indoor Rocking
 Outdoor Rocking
 Centre Break
 Double Break
 Indoor Earthing Switches
 Outdoor Earthing Switches
 Quick Make Earthing Switches
 Operating Mechanisms
 DC Disconnectors
 for Railway Applications
 Operating Mechanisms
 Switch-Disconnectors
 Outdoor Switch-Disconnectors
 Indoor Switch-Disconnectors
 Operating Mechanisms
 Switch Disconnectors
 Fuse Combinations
 Indoor Switch Disconnector
 Fuse Combinations
 Operating Mechanisms
 HV FUSES
 Current Limiting Back-up Fuses
Indoor Fuse Bases
Outdoor Fuse Bases
 LIVE WORKING
 Voltage Detectors
 Insulating Sticks
 Rescue Sticks
 Fuse Handle
 Insulating Mats



General


   Indoor earthing switches are used for ensure absolute de-energisation of medium-voltage equipment in a circuit or switchgear.

   Güral Indoor Earthing Switches offer free-standing, robust and reliable solutions for medium – voltage earthing systems. With variations designed to serve for a wide range of system voltages, Güral Indoor Earthing Switches currently operate worldwide at system voltages from 12kV to 36kV.

   The flexibility of the design of Güral Indoor Earthing Switches allows almost any custom solutions requested by the client, insulation levels, driving variations and construction assembly types.

Base and Shaft


    Indoor Earthing Switch consists of three poles. Three poles indoor earthing switches consist of a base, three support insulators, a continuous main sliding shaft (hexagonal transmission 27) and three earthing blades that moves in a vertical plane. Continuous main sliding shaft enables the optional mounting of the drive on the left or right side.

   All steel parts of the earthing switch base are hot-dip galvanized or electrogalvinized.

Insulators


   The earthing switches can be equipped with insulators in accordance with IEC, ANSI or DIN specifications.
   

Earthing Blade


    The twin sectioning earthing blades and terminals are made of electrolytic copper. Terminals and contact surfaces of blades are silver plated.

   The twin sectioning earthing blades are pressed on terminal contacts by means of a number of spiral springs depending on required contact pressure due to short-circuit capability, ensure that the current is transferred from the terminal contacts into twin sectioning earthing blades. This blade and contact construction is maintenance free.

   The contacts are self-cleaning, which makes the earthing switch suitable for installation in all areas with severe climatic conditions.

Operating Mechanism


   The earthing switches can be three poles operated by means of a motor-operated drive mechanism or a manual-operated drive mechanism.

                     Güral indoor earthing switches can be drived by any controlgear model designed by Güral; drive model is to be decided according to application requirements.

Testing


    The earthing switches are designed and tested in accordance with latest IEC standards.
   
Installation

   Indoor earthing switches are completely assembled and adjusted in our workshops. Its design permits both vertical and horizontal mounting.

   The construction is designed so that all earthing switches can be installed very easily, without the need of any special tools. For each indoor earthing switch an instruction manual for transportation, mounting and commissioning is enclosed. This instruction manual should be strictly followed.

Maintenance


    The indoor earthing switches supplied by Güral are designed so as to ensure that they are maintenance free.

   However, to guarantee a long and trouble-free service period, we advise that a visual inspection of the contacts be carried out at regular intervals.



Technical Data


Rated Voltage

Ur (kV)

12

17.5

24

36

Power Frequeny Withstand Voltage

 

- to earth and between phases

Ud(kV)

28

38

50

70

Lightning Impulse Withstand Voltage

 

- to earth and between phases

Up(kV)

75

95

125

170

Rated Short-time Withstand Current

Ik(kA)

Up to 50kA/1s

Rated Peak Withstand Current

Ip(kA)

Up to 125

Mechanical Endurance Class

 

M1

Class of Earthing Switch

 

E0


Dimensions (mm)
Dimensions having (*) is changing acc.to rated current of disconector.
Dimensions having (**) is changing acc.to client's specifications.

 

Dimensions (mm)

Type 

B(**)

C(*)

E(**)

F

H

L(**)

DTA12

210

250

586

355

165

810

DTA17.5

280

295

706

405

165

930

DTA24

300

330

746

460

165

970

DTA36

400

420

986

550

165

1340

 
   
WORKSHOP
Atatürk Sanayi Sitesi, Fahri Korutürk Caddesi, 323 Sokak, No:1, 34900
Hadımköy – ISTANBUL / TURKEY
Tel: +90 212 771 24 95-99 / 771 27 60-61     Fax: +90 212 771 27 62
OFFICE
Rıhtım Cadddesi, C Blok, No:59, Kat:2, Daire: 25, 34425
Karaköy – ISTANBUL / TURKEY
Tel: +90 212 249 82 80      Fax: +90 212 244 25 07
 
 
copyright © 2007 Güral Elektrik Malzemeleri Ticaret ve Sanayi A.Ş.
Project By