DISCONNECTORS
 HV Disconnectors
 Centre Break
 Pantograph
 Horizontal Break Pantograph
 (knee type)
 Earthing Switches
 Operating Mechanisms
 MV Disconnectors
 Indoor Rocking
 Outdoor Rocking
 Centre Break
 Double Break
 Indoor Earthing Switches
 Outdoor Earthing Switches
 Quick Make Earthing Switches
 Operating Mechanisms
 DC Disconnectors
 for Railway Applications
 Operating Mechanisms
 Switch-Disconnectors
 Outdoor Switch-Disconnectors
 Indoor Switch-Disconnectors
 Operating Mechanisms
 Switch Disconnectors
 Fuse Combinations
 Indoor Switch Disconnector
 Fuse Combinations
 Operating Mechanisms
 HV FUSES
 Current Limiting Back-up Fuses
Indoor Fuse Bases  
Outdoor Fuse Bases
 LIVE WORKING
 Voltage Detectors
 Insulating Sticks
 Rescue Sticks
 Fuse Handle
 Insulating Mats




General


To operate the poles of switch disconnector-fuse combinations with or without earthing switches, either manually or electrically, we propose a complete range of mechanisms, suitable for our switches, but also, with some minor adaptations, to switches of other manufacturers.

Güral MVMD, SHD series operating mechanisms offer the multiple features necessary to operate the indoor switch disconnector-fuse combinations with or without earthing switches either locally or remotely (MD), in the best condition of safety for the operator and the grid.

Güral MD, MVHD and HK series operating mechanisms offer the multiple features necessary to operate the outdoor switch disconnector-fuse combinations with or without earthing switches either locally or remotely (MD), in the best condition of safety for the operator and the grid.

They are designed to ensure the highest reliability over years, with the use of corrosion-free materials for the enclosure and external devices. The inner components (MD, MVHD) are protected by the weatherproof cabinet IP 55 and by anti-condensation resistors.


MVMD Series Indoor Motor Operating Mechanisms


Güral MVMD Series Motor Drives are driving solutions for almost any type of mechanically driven electrical devices. The flexible configuration capability and optimized characteristics of MVMD units for medium voltage system devices and DC disconnectors have proven Güral  MVMD Series Motor Drives as one of the leading choices all over the region.

All MVMD Series Motor Drive Unit configurations are tested to satisfy IEC 60694




Terminals
High quality terminals enables easy user cabling. Terminal quantity varies by product configuration.
Contactors
High quality contactors controls the motor behaviour according to user commands.
Drive Shaft  
Drive shaft conducts the mechanical torque to optional driving arm.
Motor Protection Switch   
High quality motor protection switch protects the motor from anymechanical / electrical overloads and ensures the product endurance.
Security Switches             

Security switches prevents any electrical operation during manualdriving and protects the user from undesired mechanical forces.

Limit Switches                   
Adjustible limit switches enables the user to control the driving angle and limit driving arm positions.
Motor   

High quality, IEC compliant motor units promises reliable operation, long endurance and low energy consumption.

Motor Carrier                     
Special designed motor carrier plate enables double side motor assembly (right or left) and is tested against 3.5Fmax to ensure unit robustness.


Technical Specifications & Options For MVMD Series Motor Drives


Standard Specifications

 
Controlling Capabilities Remote & Local

Operating Capabilities      

Motor & Manual
Operating Time Operator dependent
Security interlock /w other units Electrical
Displacement 108 to 181 mm linear

Other Units & Accesorries

 

 

 

Electrical
AC or DC supplied Mo tor Unit
Motor Protection Switch
Security switches
Limit Switches
Contactors
Standards satisfying wiring
Easy-install terminal blocks
Mechanical
4 point assembly plate
Manual driving arm
Anti-corrosion
IP55 Class protection for motor units
Electrogalvanized metal components, with minç plating thickness @ 20µm
User
In-bag wiring diagram, User Guide and other documentation

Options

Control Circuit Supply Voltages

DC 24V, 48V, 110V, 220V.
AC 110V, 220V

Motor Supply Voltage

DC 24V, 48V, 110V, 125V, 220V
AC 230V – 1Ø, 380V – 3Ø

Auxiliary Switch Types

2NO + 2NC, 4NO + 4NC, 6NO + 6NC,  8NO + 8NC,

SHD Series hand operating mechanisms


SHD Series hand operating mechanisms are only used for the operating of indoor switch-disconnectors, indoor switch disconnector-fuse combinations and for their earthing switches.

The position of the hand drive bar (when the disconnector is closed-Picture 1 and when the disconnector is open -Picture 2) is shown in the pictures below. When the disconnector is closed, the bar must be perpendicular to the ground and when the disconnector is open, the bar must be parallel to the ground.


                               Picture 1                       
Picture 2


MD Series motor operating mechanisms


Güra MD series motor drives is the result of many years of continuous improvements in the field of reliability and easiness of use. MD series motor drives are manufactured in several types, the overall dimensions of the mechanism remains the same, in some special cases, optional accessories are installed inside the housing due to customer request.

MD Series motor drivess can carry out the electrical operation of the driven device; by means of an electrical motor which drives a chain system driving the vertical mechanic load terminal shaft, or the manual operation of the device, by means of a crank to be inserted to excite the chain mechanism.

MD Series motor drives are generally supplied to carry out 90º rotation on the mechanical load terminal shaft, but in some special cases due to customer request, the driving angle can be pre-adjusted for different angles.

Integrating selected and tested components, it can operate within the standard IEC temperature range (-25/+ 40°C ), but also, upon request, down to -50°C and up to 50°C .

The motor and auxiliary voltages can be chosen according to the available supply on the substation, AC or DC, from 110 V to 400 V.MD Series motor drives supplied by Güral are designed so as to ensure that they are required first  maintenance after 1000 switching operations.

 All MD Series motor drive configurations are tested to satisfy IEC 60694.


Technical Specifications For MD Series Motor Drives


Standard Specifications

Local & Remote
Operating Capabilities Motor & Manual
Operating Time 7-9 sec for half-cycle.
Security interlock Mechanical & Electromechanical
Other Units & Accesorries

 

 

 

Electrical

Motor protection switch
Local & Remote switch
Adjustable limit switches
Security switches
MCB fault signals
Local position signals
Manual driving signal
Standards satisfying wiring
Easy-install terminal blocks

Mechanical

4 point steel-construction assembly bar
Inter-units mechanical interlock
Electromechanical operation lock
Mechanical cover lock

Anti-corrosion

IP55 Class protection
Aluminium alloy casing
Electrostatic case painting @ 70µm
Heating Resistor, auto-controlled by adjustible thermostat
3 point conditioning airways

User

In-case wiring diagram, user Guide and other documentation
In-case manual driving arm
Integrated inner lighting

Options

            

Rated Supply Voltage

AC 110V/1Ø, 220V/1Ø, 380V/3Ø
DC 110V, 220V

Rated Control Circuit Voltage

AC 110V, 220V
DC 48V, 110V, 220V

Applicable Auxiliary Switch Types

2NO/2NC, 4NO/4NC, 6NO/6NC, 8NO/8NC,10NO/10NC, 12NO/12NC.


MVHD Series hand operating mechanisms


Güral MVHD Series Hand Drive Units offer a robust manual driving solution for almost any applications and climates. MVHD Series Hand Drive Units find widespread application area, including medium voltage networks, DC applications and railway solutions. MVHD Series Hand Drive Units are designed of capability to serve in harsh outdoor conditions, including very cold climates with minimum average temperatures down to -40°C (-32°F) and very hot climates with maximum average temperatures up to 50°C (122°F).

MVHD Series Hand Drive Units arrives in its water - proof case with full equipment and user guides.

All MVHD Series Hand Drive Unit configurations are tested to satisfy IEC 60694.



1. Handle                      

The polyamid handle is designed for an easy grasp.

2. Operating Arm         

The hot deep galvanized operating arm of460mm enables a torque ratio of 1/6,minimizing the effort needed to drive anydevice.

3. Mounting Flange

The mounting flange is St 37-2 alloy, and the steel is protected against corrosion by120µm hot deep galvanisation. Connectionis made by 2xM12xL bolts, 2xM12 springwashers and 4xM12 plain washers, as explained on the overall layout drawing.

4. Driving Arm

The driving arm is composed of non-corrosive parts, and is compatible with 1"connection pipes or rods. The rotationability in both XZ and XY axises provides MVHD units' assembly flexible and possible on any supports. Please see details below.

5. Position Label

The color aluminium label indicates the position of the MVHD and the drived unit.

6. Lock

The optional lock provides extra security against unauthorized operations.

7. Release Button

The water-proof release button energizes the locking coil to enable manual operation.

8. Casing

The casing is made of 2.5mm aluminium, and is electro-static painted.

9. Frontal Cover

Assembled by corrosion-proof inox bolts, the aluminium frontal cover is removable for any inside operations by the operator.



1. Thermostat

The thermostat is adjustable to maintain the inside temperature between 0 to 30ºC. The default value for the thermostat is 25ºC

2. Core Mechanism

The core of the unit is made up of Zn plated steel components and the electromagnetic coil operating at the preferred auxiliary voltage.

3. Auxiliary Switch

The auxiliary switch is optional for MVHD units, and can be ordered as from 2 to 8 NO/8NC contacts.

4. Terminal Blocks

High quality terminal blocks are tested to comply with IEC 60694 dielectric tests. The quantity of blocks are determined by the electrical component composition of the unit.

5. Heating Resistor

The heating resistor is a standart component for MVHD units to assure the proof of corrosion inside the unit and the long endurance of electrical components in harsh environmental conditions.

6. Upper Airway

Upper airway lets the moisture and excess heat out, while keeping dust and other unwanted environmental particules away.

7. Lower Airway

IP 55 airway to let fresh air in.

8. Lower Cover

The lower cover is an electro-static painted aluminium plate and is assembled to the main case by INOX bolts. It can be drilled for cable entry or entirely removed to be replaced by custom covers designed by the user.


Pipe plug-in



1. Pipe Connection

The pipe connection is compatible with 1" pipes.

2. Double axis cantilever

The rotation ability of the cantilever in both XZ and XY axises provides MVHD units' assembly flexible and possible on any type of supports.

3. Support Connection   

The M16x75 HDG bolt and the M16 HDG nut connects the driving arm to the operating arm. The driving arm can be dismounted by releasing the connection nut and bolt, in case of any need to ease the pipe connection to the pipe connection component. If needed, the driving arm can also be mounted on the opposite side ofthe operating arm, to inverse the driving direction


MVHD Series Hand Drives Technical Specifications & Options


Standard Specifications

 

Controlling Capabilities                            

 Local

Operating Capabilities                                  

 Manual

Operating Time  

Operator dependent

Security interlock /w other units           

Electromechanical

Displacement                                             

150mm vertical

Torque conversion ratio                             

 1/6

Case Color                                            

RAL 7032

Other Units & Accesorries

       

    

             

Electrical
Security switches
Manual driving signal
Standards satisfying wiring
Easy-install terminal blocks
Mechanical
4 point steel-construction assembly bar
Inter-units mechanical interlock
Electromechanical operation lock
Mechanical operation lock
Mechanical cover lock
Position indicators
Anti-corrosion 
IP55 Class protection
Aluminium alloy casing
Electrostatic case painting @ 70µm
Heating Resistor, auto-controlled by adjustible thermostat
2 point conditioning airways
User 
In-bag wiring diagram, User Guide and other documentation

Options

Electromechanical InterlockSupply Voltages

 

    

  

DC 24V, 48V , 110V, 220V.
AC 110V, 220V
Auxiliary Switch Types
2NO+2NC, 4NO+4NC, 6NO+6NC, 8NO+8NC

Inner Conditioning Equipment

Adjustible thermostat 30W Heating Resistor at supply voltages: DC 110V or 220V, AC 110V or 220V.


HK Series outdoor hand operating mechanisms


HK series outdoor type hand drive mechanisms are used for operation outdoor switchgear such as disconnectors, switch disconnectors, switch disconnector-fuse combinations and earthing switches.

There is only one type of HK series outdoor hand drive mechanisms with padlocking facility.

HK series outdoor type hand drive mechanisms can be used together with standard articulatory system.

When lever is in up position disconnector or earthing switch is closed, in down position is closed.
            

Articulatory system


 
   
WORKSHOP
Atatürk Sanayi Sitesi, Fahri Korutürk Caddesi, 323 Sokak, No:1, 34900
Hadımköy – ISTANBUL / TURKEY
Tel: +90 212 771 24 95-99 / 771 27 60-61     Fax: +90 212 771 27 62
OFFICE
Rıhtım Cadddesi, C Blok, No:59, Kat:2, Daire: 25, 34425
Karaköy – ISTANBUL / TURKEY
Tel: +90 212 249 82 80      Fax: +90 212 244 25 07
 
 
copyright © 2007 Güral Elektrik Malzemeleri Ticaret ve Sanayi A.Ş.
Project By